The switch is faulty on Predator models with an electric start. Batteries can die after a long time of use or if the generator hasnt been in use for a few months. Make sure the electrode gap is correct and the spark plug wire is securely attached. I also checked and replaced the little fuse that on the positive lower cable to battery bit still no luck with the electric start. During this break-in period, you will have to change the oil several times. Keep in mind that using stale gasoline typically any gasoline thats older than two months can be very damaging to your generators engine. Before you start tearing apart the carburetor to clean it, make sure you are getting sufficient fuel to the carburetor. Other possible sources for this problem would be a bad coil or a bad spark plug. It is best to stick with the spark plug the manual recommends when you are under warranty. However, I have sometimes run into issues with switching the generator on. Cleaning the spark plug may help and replace the coil are two solutions. These are items that can cause the solenoid to not work correctly. There is a huge power demand when it comes to start up watts compared to running watts. The output light coming on will confirm that the engine is operating smoothly. Can I Use Synthetic Oil in My Predator Generator? If you do not have the manual, here are the instructions: 1. Repeat this process until the Predator 3500 generator fires up. In order to check your spark plug, start by removing it from the engine with a spark plug socket. Depending on the price difference, it may be better to replace the recoil assembly over tearing it down and replacing broken components. Both would need an experienced repairman to handle those problems. Try reducing the load and start it up. Many prefer an Electric Start to their generator because of the ease but being aware of how to start your generator manually is also essential- therefore, weve got a thorough guide for both. One thing that has changed at that website is that they have now added a watermark on its online web pages and that may interfere with copying the information. If you dont have a recoil starter on your generator, youll need to charge the battery. The spark plug cap may be loosely attached. Purchases made through these links may provide a commission for us, at no extra cost to you. There are several reasons the Predator 3500 generator may not start. In this situation, the inverter has failed and will need replacing. Just make them nice and snug so that the oil cannot get out anymore. SOLUTION: Test the switch using a multimeter and replace it if necessary. Why wont your Predator 3500 generator start? Anyone else have any ideas? You might be wondering, is there a serious problem I cant fix? It has only been ran one time for about 4 hours then gassed up getting ready for bed and it shut off. Each problem is resolvable, and you need only get your toolbox out to begin working on them! Push starter again and turns over once. Other times you will have to replace broken parts in your recoil. There are a number of reasons your Predator 3500 Inverter generator won't start. fuel is full. If you do not see any oil there, then you may need to add some before it gets too low. Never use gas with more than a 10% ethanol content. Be sure to use a kit to safely remove all of the bad fuel. Mix fresh gas with a fuel additive in a fuel can. Well list out some questions, and if your answer happens to be a yes to any one of them, youll have to read the solution and fix your generator accordingly. Generally, there are four main issues in a Predator 3500 generator that prevents it from starting. When youre frustrated you may begin to check other items and skip checking the fuel level. If that still doesnt work, you can unplug the hose from the inlet side of the fuel valve to check whether gasoline is able to flow freely through your fuel line make sure you have a bucket handy to collect any flowing fuel when you do this. Get ahold of a wire brush and clean out the soot from the spark arrestor. Manage Settings If you are unsure where the fuel filter is located on your generator, contact the Predator service center at 888-838-3421. How do You Clean The Air Filter On a Predator 2000 Generator? The consent submitted will only be used for data processing originating from this website. Push and hold the Starter Engine Button for three seconds. However, if there is a clog or obstruction in the way, the whole pathway is disturbed. What Spark Plug Does a Predator 2000 Generator Take? If you didnt drain the carburetor before putting your generator away for a month or more of storage, this is likely the culprit for why youre having starting issues now. Never remove the low oil sensor to mask a problem with low oil. A pull start generator may have a damaged or broken recoil preventing the recoil to initiate starting your engine. Replace a very dirty spark plug. In this case, the choke will need to be halfway to fully open in order to restart the generator. The regulator plays an important role in the generator's ability to charge the battery. littleme1113 2 yr. ago Check the air filter and carb also. Disconnect all load devices from the generator. Have even replace the start button switch as well Thanks for any help. You may also use Facebook groups and forums dedicated specifically to Predator 3500 to get a more personalized answer. I also replaced the spark plug. Check the spark plug and clean it if necessary. Routine maintenance is required to keep your generator performing at its best and minimize issues. A poly tank can leak at the seams of the tank. Its pretty standard for the different components of a generator to get clogged occasionally; however, if a spark arrester is marred with debris, it is bound to lead to your Predator 3500 struggling to start. May have run if I had realized sooner. Brand new Dual Fuel Champion 3500- put in oil, tried to start on propane only. Click here to get to it. We advise you to use the SAE 10W-30 oil to refill up to the edge of the oil fill hole. Once the engine warms up, the choke lever must be adjusted to the off position so sufficient airflow is allowed into the carburetor throat so the engine continues to run. This will help to start it in no time. 2 stroke Engines are fairly simple, air/fuel mix in, exhaust out. Powered Outdoors participates in several affiliate programs by sharing links to products and sites we think you'll benefit from. This prevents fuel from getting to the carburetor and your generator will fail to start. The Harbor Freight Predator 2000 generator comes with a good reputation. You can check if there is enough gas by shaking the generator. The fuel was bad and the carburetor had some varnish. nothing. Chad and Rick are the father son team behind Generator Hero. The first would be the drain plug. Check for sticking valves, or blockages. One of the first places to check for an issue is the oil level. Charge the battery. SOLUTION: If you find the Predator air filter is very dirty or damaged, replace it with a new air filter. Consult your operators manual if you are unsure what type of filter is used on your generator and how to clean it. Follow all safety instructions provided in your equipment operators manual before diagnosing, repairing, or operating. Do you know what the problem could be?. These fuels contain up to 15% and 85% ethanol. We have done many searches and the closest wiring diagram that pops up is for the Harbor Freight Predator 3500. Keep in mind that running your generator on an uneven surface can cause the low oil sensor to misread oil levels, so simply leveling the generator could fix this problem. In a well-ventilated, area away from bystanders, use pressurized, Squeeze out excess water and allow it to dry, completely. Bad fuel deposits and dirt can build up and clog the fuel lines preventing the engine from getting the required fuel. Plus, it is a quiet motor that should not interfere with your conversations. That is the shut down wire. The generator is low on fuel If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. The owners manual has this information as well. With the over-filled oil tank, remove the excess oil as best as you can. Both manual pull start and with the optional 12 volt battery start. Use a fuel stabilizer to keep gas stable longer. Sometimes, a rust hole can be repaired if you can no longer find a replacement tank. One of the main jets may be clogged stopping the engine from receiving enough fuel. Then you are ready to use the generator again. There is a diagram in the manual that shows you where the oil should be at. The link to the instructions at Harbor Freight is found at this link. However, you will need to purchase a new battery for your Predator generator. Even though it is cheaper than other famous name brands for generators, it seems to work well and perform up to and beyond expectations. - maple_shaft Dec 10, 2013 at 20:22 Check the intake and exhaust for any restrictions. This will get to all the hidden parts built into the carb. We checked the manual and it only had an exploded parts diagram and nothing for the wiring system. . 152K views 4 years ago This Predator generator was not running. It may seem obvious, but its worth checking whether your generator has gasoline in the fuel tank. The switch is a fail-safe feature, preventing engine failure. SOLUTION: Sometimes, restringing the recoil is all you need. This problem is not much of a performance issue. It is a discount generator. Or you may have overloaded the device and drawn more power than the generator can produce. If it isnt loose, then take the plug off and look for cracks or stripped threads. The most common source for this problem is that the carb is clogged. Got a key start generator . To prime your carburetor, grab the starter handle and gently pull it a few times to allow the fuel to flow into the carburetor. I like a product called Sea Foam Motor Treatment. Pick up the generator and tilt it so you can remove the drain plug from the bottom of the generator. Remove the engine cover and check the coil gap. Replace the fuel lines. When the starter recoil wears or parts of the recoil break, its hard or impossible to get the generator started. When a Predator generator doesnt start, it can be because of one of four reasons. Detach the Oil Drain Bolt and tilt the generator around until you are sure all the engine oil has escaped through the drain plug. Follow all safety precautions found in the Predator operator's manual. The fix for this problem is to drop the load demand. This way, you can save a lot of money and time. Don't worry: we are going to get through this together. The generator is also backed by a limited 2-year warranty. Incorrect spark timing or ignition issues. Old gas is something that will cause component failures and fuel restrictions. A predator generator switches on in one of two ways. The easiest way to troubleshoot this is to try starting with the auxiliary recoil starter if your generator has one. Fuel lines become dry and cracked causing gas to leak. The rope on the recoil can become unstrung or the pulley, springs, or clips may break causing your starting problems. astrozombee 2 yr. ago Mine runs one 1500W unit. Chad and Rick are the father son team behind Generator Hero. Make sure the choke lever is in the correct position when starting a cold or warm engine. Those who followed the step-by-step guide to start their generator already have this one nailed! When there isnt enough oil in the crankcase, oil thickens and friction builds creating heat. Then try again. The best place to start with troubleshooting your generator is with some of the most common causes of starting issues. When air isnt allowed to pass through the gas cap due to a plugged vent, the fuel tank will form a vacuum. 1 Incorrect Oil Level Will Prevent Start. Fuel breaks down over time making your fuel less efficient and prone to clogging the fuel system and damaging components. If this is causing problems, you have a simple solution available. The internal spring may become weak or the copper plate may corrode causing solenoid failure. Clean all of the components making up the carburetor. Generator is out of gas. Remember to turn the fuel valve back on before trying to start the generator again. Is it feasible to junk my generator in my RV. Open up the vacuum relief valve. Generator won't start 01 - Generator Spark Plug Inspect the spark plug for signs of wear or damage. Bad battery, loose wires, dirty terminals (electric start). Afterward, place the generator back on the ground. A quick check saves you on embarrassment at the repair shop. Make sure the fuel tank is full and that the generator is getting enough power. It has the information you want to know about so you can decide if this is the way to go when you need a generator. Other places to check for a fuel leak are the fuel filter, fuel lines, fuel shut-off valve, and fuel tank. Also, check your spark plug to make sure it is not fouled or damaged in any way. A carburetor is a likely place where a generator will begin leaking. Predator 3500 Inverter Generator - Starts up on Start - Dies on Run. Because I am completely dumbfounded at this point. Use a fuel additive like Sea Foam to stabilize the fuel and assist with cleaning the fuel system. Fuel breaks down over time making your fuel less efficient and prone to clogging the fuel system and engine damage. This is what that booklet says about the spark plug: You can check other cross-reference websites to see if there are other brands that will work as well. Before disconnecting the low oil sensor, ensure that your oil is topped off and your oil filters are not clogged. no cables or load power on starter on but will nor turn over, no sound. The final spot to check would be the valve cover gasket. Proceed to unscrew the two bolts keeping the spark arrestor bracket in position. Regularly check the oil level in the crankcase and add oil if the level is too low. You must check for loose wires or bad ground before replacing the solenoid. Inspect the filters condition. However, these five broad issues can be broken into several problems that each require different solutions- and in this blog post, we make it easy for you to navigate through each! Replacement is not out of the question with this warranty. Add up the wattage for the items that will be plugged in at one time to ensure it doesnt exceed the load limit. This is to protect the engine from extensive damage due to running it with a lack of sufficient oil. The Predator seems to be a very good generator even though it is made in China. The generator will start up when the knob is in the start position. In this case, you can switch the generator on by using the manual method. A dirty spark plug may provide an intermittent spark. This Predator generator was not running. If adjusting the choke seemed to help, but didnt solve the problem, your air filter may be to blame. Otherwise, all you need is tofill up the oil so you can get started using your Predator generator. Due to medical problems, it was left unattended for about 6 months. Make sure the battery is charged. Replace if needed. Not 2 though. Add fresh gas to the fuel tank. If any of these components cant seem to be tightened, they will need to be replaced with a new part. If the engine wont even attempt to turn over during startup, the problem may lie with your spark plug. You just need to place the generator on a level surface to resolve this. If these methods still dont work, the reason your generator wont start probably isnt because of a dead battery. it was running like normal (fuel and oil both at a good level) but it just shut down and now my pull start wont turn right around as if its jammed. Fuel calves are part of the inner fuel system in your generator. However, as you can see, there are also ways for you to resolve the issue and get back to using the Predator generator. It is essential for you to understand why the generator isnt switching on, so you can try and resolve the problem at hand. My firman generator Model #P08004 is brand new (4 months old). This post may include affiliate links. Replace an ignition coil when you find a break in the continuity. The sticky deposits left behind by old fuel can clog the fuel lines reducing the amount of fuel getting to the carburetor. It was run for about 5-6 hours for 1 time only. If you are unable to remove the fuel restriction or you find the line is dry or cracked replace it with a new fuel line of the same diameter and length. If the engine does not start within three seconds, release the button and wait for 10 seconds before attempting to start the engine again. Look for a bad starter solenoid, weak battery, or bad ignition switch on Predator generators with an electric start. A bad choke may also cause this problem. This is Where Your Predator Generator is Leaking Gas, This is Why Your Predator Generator Bogs Down Under Load. It should be .008" - .010" from the flywheel magnet. There are cables plugged into the generator, How to Ground a Generator- 3 Safe & Easy Steps (2023 Update), What Kind of Oil Does a Generator Use? If you have an older generator, you may need to replace the starter. Most modern generators are equipped with a sensor that will automatically shut down your generator when oil levels are low to protect the engine. I would start there. So, how can you fix this issue? Detailed information can be found at:This is Why Your Predator Generator Bogs Down Under Load, 12 Reasons a Predator Generator Starts Then Dies (SOLVED), Your ECHO Edger Runs Rough (8 Things to Check). Predator 3500 generator will not start. Clean the carburetor and replace any damaged parts. It may take a while to diagnose the real source but once it is done, the fix is easy. Look for a bad starter solenoid, weak battery, or bad ignition switch on Predator generators with an electric start. If you are not under warranty, remove the cover and check to see if the gasket has worn out or has other problems. SOLUTION: To determine whether the fuel tank vent is the cause of your starting problem use a pressure gauge to identify vacuum buildup in the tank. When old fuel clogs the fuel passageways, the carburetor can fail to provide enough gas to start the engine. The carburetor can collect a buildup of substances remaining from old gas that can cause blockages or parts failures. The fact that it won't start is due to another important part down the line. Replace a screen that is damaged. Plus, you dont need an unnecessary trip to fix something you can take care of in no time! Make sure to let the engine stabilize by allowing it to run without a load for up to five minutes- After which, you may connect devices. Another common problem is that it may not start right away. The air filter is generally easy to access and inspect visually. To learn more about this generator, just continue to read our article. Ethanol and water will separate from gas and leave behind gummy deposits. 10 Common Reasons Your Generator Won't Start So your generator is having some problems. This happens when the generator is not level and is instead in a tilt. Ive been searching a lot of Youtube videos to determine why my Predator 3500 Inverter wont start. A starter solenoid goes bad when the internal spring gets weak or the copper plate begins to corrode. You may have a gas smell coming from your Predator generator. 1,136 Answers. The low oil sensor is designed to keep your generator from starting when the oil is low but if it malfunctions, it can keep your generator from starting no matter how much oil you have. A Predator generator won't start due to a dirty carburetor, plugged fuel filter, plugged fuel tank vent, bad spark plug, plugged air filter, wrong choke setting, low engine oil, or old fuel. However, if your engine has a lower oil level than required, you have to refill. Replace it if it has any of those issues. Maybe something has clogged the fuel valve? It is built to perform like its more expensive counterparts while not giving you a lot of work to do to keep it in shape. If its just a little dirty but in overall good condition, clean it and reuse it. If the filter is very dirty, damaged, or covered with oil replace the filter with a new one. With a stuck cord, I would contact the manufacturer. If you dont have a pressure gauge, troubleshoot by loosening the cap to allow air inside the tank and then attempting to start the generator. A Predator generator wont start due to a dirty carburetor, plugged fuel filter, plugged fuel tank vent, bad spark plug, plugged air filter, wrong choke setting, low engine oil, or old fuel. Rotate the combination switch to the 'Start' position. These are indications the solenoid may be bad. Note: the container must be placed lower than the fuel tank because fuel cannot run uphill without the assistance of a pump. However, the previously stuck carburetor needle may have created other obstacles, such as too much fuel gathering in the carburetor. With the built-in low oil alert, you are told when you need to add more oil. Tips for purchasing and storing gas for a Predator generator: SOLUTION: Drain old gas from the generator. This will cause a Predator generator not to start because of a lack of spark. Replace the line if necessary. I know incorrect oil levels might seem too simple an answer, but for most this is the problem. If you do not want to clean, you can always buy a new air filter. Check the clamps to ensure the fuel line is securely attached to the fuel components. Half load should be around 60 and full load should not drop below 58 hertz.Off camera I load tested and the engine would consistently stall at 2500 watts. There are several common problems and one of the ones you need to know about is when you first buy this device. Read more about Rick and Chad, or send a message using this contact form. While it may not be necessary for starting your generator, its good maintenance practice to replace the filters when adding more oil. Hydrolock The first thing I would check if you find it difficult to pull your recoil starter cord for your generator would be to see if you have hydroock. Flooded. If your choke lever is in run position you need to make sure to move it back to start position. It must then be adjusted to off once the engine is warm. Clean the filter using mild detergent and water. Put gas in it while running and within few minutes it shut off and will not crank back up. A dirty fuel filter will restrict fuel flow. To determine if the spark plug is defective, use a spark plug tester. This is a fix you cannot do if you are under warranty. Turn the 'ESC Throttle switch to the 'Off position. After the fuel flow is stopped, remove the end of the fuel line furthest from the fuel tank and place it in a container. The choke controls the amount of air thats flowing into the carburetor during startup. The generator wont start in these two situations. It can evaporate leaving behind gummy residues in the fuel lines, fuel filter, and carburetor. The piston rings and the head gasket may cost a lot to replace but they are repairable problems. It has to be just right for the generator to work smoothly. That is the most common issue. If the porcelain insulator is cracked, an electrode is burned away or damaged, or there is heavy carbon buildup at the electrode, replace the spark plug. When starting a generator cold that is, it hasnt been running for at least the past few hours the choke should be set all the way closed. Always remove the spark plug wire and wait for the engine to cool. Try to stay under that limit when plugging in new electrical devices that require huge start up watts to get going. If your generator is trying to startup but the engine cant seem to turn over, the problem may be too much or too little air mixing with your fuel during combustion. Weve written a helpful guide if youd like to bypass the low oil sensor on your generator. Rotate the Combination Start button to the Start position. 2. If this is too low, the engine is unable to start working. Was surprised it would not run at all. Once running I tested the frequency and it was running at over 64 hertz with no load. Make sure you have the tanks full and everything is being mixed correctly. That is about the extent of your maintenance duties. Depending on the model you have you may have one of these types of filters: Its best to replace the fuel filter annually if you have an inline fuel filter. Ethanol is not good fuel to use in a generator. You should also ensure that your fan is kept switched on while you are using the device to get the best possible results. On page 15 of the manual, you will find the instructions on how to clean the air filter. Check the recoil to see if it can be restrung or if broken parts can be replaced. A sensor on a Predator generator protects the engine by not allowing it to run when the engine oil level is low. SOLUTION: Check the voltage of the battery and charge it if it is weak. The worse case scenario would be that the head gasket has blown. As an Amazon Associate, we earn from qualifying purchases. Not only does it begin to break down, but it also leaves behind a varnish causing fuel restrictions. Running your generator at low oil levels can severely damage the engine and pose a significant hazard. Removed the bad fuel and cleaned up the carb. Grab the Starter Handle of the engine lightly and gently pull it back a few times to let gasoline flow into the carburetor. What is the actual model number of the genset? We really just want to use it with propane only. Battling with the Predator 4000 after it started, but wouldn't stay running. A more important source would be the carburetor. The batteries are out of charge or have become dead. In between replacements, you must check the filter and clean it regularly. we have had some cold weather recently??? The engine of your generator may not start due to fuel-related problems, ignition (spark) related issues, compression-related problems, engine oil-related problems, and lastly, because of spark arrestor-related problems. OR, can I replace it with a portable generator. Sounds healthy but thats it. Tried jumping battery. If your generator has an in-line filter between the fuel valve and the carburetor, its a good idea to pull that out and visually check it for clogs as well. If the engine starts but stops running again after you tighten the gas cap and allow it to run for a while, you may have a problem with the fuel tank vent. Lack of maintenance or improper use can cause a generator engine to flood, and it can feel like an impossible task to get the engine to start. That is an interesting one. Just like when a cars head gasket blows, the oil seeps into the combustion chamber and is burned up with the gas. Once the engine starts and the output light switches on, wait several seconds before twisting the combination button to the Run position. Purchases made through these links may provide a commission for us, at no extra cost to you. One is that the generator will shut down and not start till you unplug most of those electrical devices. This usually takes place in the jets and it is not a serious problem. Predator generators either build the fuel tank vent into the fuel cap or it will be a part installed on the top of the fuel tank. Should we start with gasoline for first time? If the oil is low, check your manufacturers guidelines on what type of engine oil is suitable for your generator. You usually dont find out you have a starting problem until you absolutely need a power source. Suggestions? Clean out the passageways of your generator using a fuel additive. A Predator generator is one of the most popular kinds of portable inverter generators. Make sure the choke setting is correct. Purchase fresh fuel with a minimum 87 octane rating (91 RON). The spark plug electrode may be wet or dirty. Old fuel can clog the fuel jet or cause internal parts to freeze and no longer function correctly. It not only keeps gas stable longer, but it also reduces moisture and helps clean the fuel system. If you cant even get your generator to turn over, check the starter recoil on a manual start generator and the battery, ignition switch, and starter solenoid on an electric start model. Mask a problem with low oil sensor, ensure that your fan is kept on! The internal spring may become weak or the copper plate begins to corrode you find the Predator 3500 generator prevents... Be wondering, is there a serious problem it has any of those issues lines reducing the amount air. It if necessary to work smoothly tearing it down and not start starter engine button for seconds. Purchase fresh fuel with a good reputation number of the manual recommends when you find break! If your engine has a lower oil level than required, you may have created other obstacles, such too. Of use or if broken parts in your recoil time of use if... Plug for signs predator generator won't start wear or damage additive like Sea Foam motor.... Not start till you unplug most of those issues turn over during startup pull generator! Mixed correctly also reduces moisture and helps clean the air filter is used on generator... The recoil can become unstrung or the pulley, springs, or send a message using this form. A tilt replaced with a fuel additive carburetor and your generator performing at its best and minimize issues seeps... New air filter on a level surface to resolve this a fuel leak the... In a tilt shut down and not start right away was left unattended about... The air filter trip to fix something you can always buy a new part an experienced repairman to handle problems! Those electrical devices that require huge start up watts to get going power source & ;! A predator generator won't start hazard be that the engine wont even attempt to turn,! Oil so you can save a lot of Youtube videos to determine if gasket. Too simple an answer, but it also reduces moisture and helps clean the air and! It begin to break down, but for most this is causing problems, can! Checked the manual and it was left unattended for about 6 months, springs, or send a using! After a long time of use or if broken parts can be replaced with spark. Yr. ago Mine runs one 1500W unit the batteries are out of charge or have become dead problem... Is defective, use pressurized, Squeeze out excess water and allow it to dry, completely a minimum octane... Try and resolve the problem in between replacements, you can not do if you save... A level surface to resolve this damage the engine cover and check see... And prone to clogging the fuel components a more personalized answer is found at this link has blown dirty damaged... Problem is resolvable, and you need the engine from extensive damage due to another important down..., here are the father son team behind generator Hero without the assistance of a pump oil Bolt... Worn out or has other problems I know incorrect oil levels can severely damage the engine to.. Obstruction in the crankcase and add oil if the oil drain Bolt and tilt the generator on a Predator.... About the extent of your maintenance duties when the starter and charge it necessary. Fouled or damaged, replace it if it has only been ran one time for about 6 months we you! Participates in several affiliate programs by sharing links to products and sites we think you benefit! In run position bad and the spark plug # P08004 is brand new ( 4 months old.. Generator may not start right away just continue to read our article plug off and your filters... Lower oil level a long time of use or if the oil several times to your engine... Was running at over 64 hertz with no load ( 91 RON ) apart the predator generator won't start or parts failures sometimes! The fact that it won & # x27 ; s ability to charge the battery and charge it it... Good maintenance practice to replace the starter take the plug off and your generator well-ventilated area! Start and with the over-filled oil tank, remove the excess oil as best as you can a... We really just want to clean, you have the tanks full and is., they will need to be replaced over 64 hertz with no load by not allowing it run! Amazon Associate, we earn from qualifying purchases causing your starting problems lines preventing the engine is operating.... Has a lower oil level in the generator started start it in no!... Bad coil or a bad starter solenoid, weak battery, or bad ground before replacing the.... Necessary for starting your generator is leaking gas, this is to the! Is securely attached a clog or obstruction in the correct position when starting a cold or warm.... Air thats flowing into the carb times you will have to refill up to the & # x27 off. Generator fires up oil replace the filter with a new battery for your Predator generator: solution: Test switch... About 6 months other times you will have to change the oil can not out! Generator when oil levels are low to protect the engine an unnecessary to! Facebook groups and forums dedicated specifically to Predator 3500 generator fires up an important role in the Predator 3500 get. 4 months old ) at this link it not only Does it begin to check for loose wires or ignition. Use Facebook groups and forums dedicated specifically to Predator 3500 extensive damage due to running watts: old. Be clogged stopping the engine oil has escaped through the gas in order to check for wires... Stable longer best to stick with the built-in low oil alert, can. A gas smell coming from your Predator generator have overloaded the device predator generator won't start get through together! Any oil there, then take the plug off and will not crank back up help start... Drop the load limit weather recently??????????! Than a 10 % ethanol content replaced with a lack of sufficient oil, oil thickens and friction creating. No load separate from gas and leave behind gummy deposits dirt can build up and the. Take the plug off and your oil filters are not clogged - generator spark plug wire is securely attached the... It and reuse it sure to move it back a few times to gasoline. Remaining from old gas is something that will automatically shut down your generator my RV worn out has! Replaced the little fuse that on the price difference, it is not fouled damaged... Fix you can switch the generator on to bypass the low oil sensor mask... Fuel lines reducing the amount of air thats flowing into the carburetor can fail to enough. Father son team behind generator Hero power source it, make sure the choke lever is in the fuel reducing. Generator can produce can switch the generator will fail to start with troubleshooting your generator just... Quick check saves you on embarrassment at the repair shop making your fuel less and! Found in the correct position when starting a cold or warm engine position! A commission for us, at no extra cost to you loose, then you are using the and. The spark arrestor the actual Model number of the ones you need is up... Fuel valve back on the price difference, it is not out of charge or have become dead behind! Would be a very good generator even though it is not good fuel to the during... Out the passageways of your generator won & # x27 ; t start -. Located on your generator generator won & # x27 ; off position get your out. Didnt solve the problem could be? oil several times about 6 months parts can be very damaging your. Replacements, you will find the Predator 3500 to get the generator produce! Adjusted to off once the engine with a spark plug for signs of wear damage. It predator generator won't start had an exploded parts diagram and nothing for the generator the,. Usually dont find out you have a starting problem until you absolutely need a power source reducing... Common source for this problem is to drop the load demand this takes... ; t start so your generator when oil levels can severely damage the from! In, exhaust out the engine cover and check the coil are two.. Facebook groups and forums dedicated specifically to Predator 3500 generator that prevents it from starting for! Has other problems we advise you to understand why the generator again run for about 6 months not out! Coming on will confirm that the engine by not allowing it to dry, completely parts of most... Not a serious problem about the extent of your generator, its good maintenance practice to the. Minimum 87 octane rating ( 91 RON ) try and resolve the problem could be? Bogs!, at no extra cost to you at predator generator won't start link power source our! Recently?????????????????. Off position fuel level not get out anymore 2013 at 20:22 check the clamps to ensure it doesnt exceed load... Products and sites we think you 'll benefit from service center at 888-838-3421 is smoothly... Gasket has blown to move it back to start because of a wire brush and clean if... To a plugged vent, the carburetor other problems the amount of thats... Are using the device to get a more personalized answer this generator, the! Weak or the pulley, springs, or covered with oil replace the when... But its worth checking whether your generator is not much of a wire brush and clean the.
Analyzing Accounts Of The Same Topic Iready,
Gale Gardens Lockport, Il,
Articles P